11. Mold Metal Adjustments - Centering Process - Validation procedure for injection molds

Image
The eleventh step in validating a injection mold with the overall process shown in injection mold validation flow chart is Mold Metal Adjustments - Centering Process . The steps before: 1. Mold certification  2. Dry cycle mold 3. Process stability test 4. Gage repeatability & reproducibility (R&R) test  5. Mold viscosity test 6. Balance of fill analysis 7. Gate Freeze Test 8. Commissioning (multi-cavity analysis) 9. Design of Experiments (DOE or DOX) 10. Qualification (Process Capability Study)  Purpose: After achieving a capability ratio (Cr) of < 0.75 for key part dimensions, the mold metal is re-cut to center the average to match target. Changing the metal in the mold based on the optimal process, even if it means remaking mold components due to non-metal safe conditions, is preferred vs. changing the process to get the dimensional variation centered. Otherwise the process may not be capable of achieving part specified tolerances. T...

Qualification (Process Capability Study) - Validation procedure for injection molds

The tenth step in validating a injection mold with the overall process shown in injection mold validation flow chart is Qualification (Process Capability Study) . The steps before: 1. Mold certification 2. Dry cycle mold 3. Process stability test 4. Gage repeatability & reproducibility (R&R) test 5. Mold viscosity test 6. Balance of fill analysis 7. Gate Freeze Test 8. Commissioning (multi-cavity analysis) 9. Design of Experiments (DOE or DOX) Purpose: The purpose of the qualification study is to determine if the process can meet the specified key part tolerance ranges. The first mold being manufactured to produce a molded part might be made “metal safe”. In this case, the qualification step will determine how much metal needs to be modified in the mold. Resin and colorant properties also need to be evaluated so that process capability may be determined. Once a process has been selected from performing the Design of Experiments (DOE or DOX) , the qualification study needs t...

Safety precautions for injection molding

Safety is everyone's responsibility in the workplace. Safety is most often related to good maintenance and good housekeeping. Safety needs to be an attitude that if always present in your daily activities. Employees should not be hesitant to voice safety concerns in the workplace. Management is just as committed to safety as the operators on the floor; the primary difference is that the operators are usually the closest to unsafe conditions; keep management advised of unsafe conditions. The following list includes items which should be maintained to assure a safe working environment: 1. Floor and machine should be kept free of oil 2. Floor and machine should be kept free of pellets. 3. Never reach over or under machine guards. 4. Never climb between the bars when pumps are running. 5. Retract injection. unit before entering the bar space. 6. The front gate should have an electrical, hydraulic and mechanical safety device preventing clamp from closing when the front gate is open. 7...

9. Design of Experiments (DOE or DOX) - Validation procedure for injection molds

The ninth step in validating a injection mold with the overall process shown in injection mold validation flow chart is Design of Experiments . The steps before: 1. Mold certification 2. Dry cycle mold 3. Process stability test 4. Gage repeatability & reproducibility (R&R) test 5. Mold viscosity test 6. Balance of fill analysis 7. Gate Freeze Test 8. Commissioning (multi-cavity analysis) Purpose: The purpose of the Design of Experiments (DOX or DOE) is to identify the optimum mold process and the mold process window. A solid statistical understanding of DOX is necessary. There are many different types of software that can be used to assist you in performing design of experiments properly. Use the software that you are most comfortable with. The DOE can require a large amount of time to perform depending on the number of variables selected to test. In some cases a properly conducted DOX can require 2-3 days to perform as well as additional time to measure part attributes. I...

8. Commissioning (multi-cavity analysis) - Validation procedure for injection molds

Image
The eight step in validating a injection mold with the overall process shown in injection mold validation flow chart is Commissioning (multi-cavity analysis) . The steps before: 1. Mold certification 2. Dry cycle mold 3. Process stability test 4. Gage repeatability & reproducibility (R&R) test 5. Mold viscosity test 6. Balance of fill analysis 7. Gate Freeze Test Purpose: The purpose of commissioning is to ensure that all cavities in the mold deliver the same quality, i.e., there is no difference between cavities in the mold on the critical dimensions. The time required to perform this analysis is a function of the number of cavities and number of critical dimensions. The time on the injection molding machine is minimal compared to the time required to measure the parts. However, by performing this analysis it will significantly reduce the number of parts required to test and measure for future experiments on the multi-cavity tool. A solid understanding of creating and inter...

7. Gate Freeze Test - Validation procedure for injection molds

Image
The seventh step in validating a injection mold with the overall process shown in injection mold validation flow chart is Gate Freeze Test . The steps before: 1. Mold certification 2. Dry cycle mold 3. Process stability test 4. Gage repeatability & reproducibility (R&R) test 5. Mold viscosity test 6. Balance of fill analysis Purpose: The purpose of the gate freeze test is to identify the hold conditions necessary to freeze the gate. The extent and duration of hold pressure has a large effect on the dimensional stability and outer appearance of the molded part. If the hold time is too short, the gate will not have had enough time to freeze off and sink marks could appear on the part. This is especially true of larger parts and when higher hold pressures are employed. After the mold gates "freeze", hold pressure has no effect and should be terminated at that point. It is typically better to be a little high on the hold pressure timer setting. This will cause a sli...

Increase Injection Velocity

Raising the injection velocity will reduce the time taken to fill the cavity and it is therefore possible to achieve faster cooling of the preform. However, it will also increase shear in the material. Shear is a major factor affecting overheating of the material, A.A. Generation and I.V. reduction, therefore increasing velocity will damage the PET resin. When working with hot preform method , the injection velocity will also make a significant difference to the material distribution in the finished container. Filling faster means that the preform will be colder when the mold opens and its temperature balance will also have changed. Typically, the shoulder area will become relatively cooler than the base area giving less stretch at the top of the preform. When working with warm / cool / cold preform method the temperature related effects of increasing the velocity are either greatly reduced or non-existent Oil flow into the injection cylinder must be increased. For machines fitted w...

Reduce Injection Velocity

Keeping the injection velocity low will reduce the shear that occurs in the material. Shear is a major factor affecting overheating of the material and I.V. reduction, therefore reducing velocity will protect the PET resin from excessive damage. When working with hot preform method, the injection velocity will also make a significant difference to the material distribution in the finished container. Filling slower means that the preform will be hotter when the mold opens and its temperature balance will also have changed. Typically, the shoulder area will become relatively hotter than the base area giving more stretch at the top of the preform. Excessive injection velocity can also disturb the alignment of the injection core, especially if the design is long and thin. Reducing the injection velocity will also have the effect of making the holding time shorter since the V/P time will increase. When working with warm / cool / cold preform method the temperature related effects are either...

Ensure Correct Preform Temperature Balance

Hot PET stretches more easily, cooler PET is more difficult to stretch. Therefore the primary method of adjusting the positioning of material in the finished container is to use relative temperature in various parts of the preform. If the temperature is balanced, the wall thickness of the container can be optimized and the overall strength of the container can be improved. If the balance is incorrect, some areas may become thick leading to a mottled or grainy appearance while the thin, overstretched areas such as the corners may show pearlescence or crystallization. Balance the temperature of the material within the preform to give the most equal strength in the finished product. There are two major methods of doing this. In the first method, injection velocity is used to control the temperature balance of the preform. Since most of the retained heat from the injection process is used in the blowing of the container, this method can have dramatic effects on the finished container. Fil...

6. Balance of fill analysis - Validation procedure for injection molds

Image
The sixth step in validating a injection mold with the overall process shown in injection mold validation flow chart is balance of fill analysis . The steps before: 1. Mold certification 2. Dry cycle mold 3. Process stability test 4. Gage repeatability & reproducibility (R&R) test 5. Mold viscosity test Purpose: The purpose of the balance of fill analysis is to evaluate the thermal and flow balance of the plastic distribution system in the mold. The plastic distribution system encompasses the hot or cold runner system, as well as the core and cavity. Only a naturally or symmetrically balanced manifold should be specified. The cavity-to-cavity weight difference is an indicator of the quality of the hot runner system. It is critical to have the flows balanced to each cavity or the part-to-part variation may be large and process capability may not be achievable. Recall, the purpose of the mold validation procedure is to reduce variation throughout the injection mold. A typical m...

Optimize Secondary Blow Delay (Start)

The purpose of the Secondary Blow air is to make the final shape of the container with all details. The Secondary Blow air should NOT be controlling or influencing the inflation of the preform. As with the Primary Blow Delay timer, there is no "correct" setting for Secondary Blow Delay . The optimum setting will depend on many other factors upstream of the stretch blow process and will include the setting of the Primary Blow Delay . Therefore, adjusting the Secondary Blow Delay time should be the last processing adjustment to be made when setting up a machine. As a general rule, the Secondary Blow Delay timer should be set as short as possible to get the best definition in the container, but without upsetting the blow-up of the preform. Having the Secondary Blow Delay set too short is likely to cause off center gates and neck rings. If there is too much delay between the introduction of the primary air and the secondary air, it may cause pearlescence in the corners of the c...

Optimize Primary Blow Delay (Start) for ISBM

The purpose of the Primary Blow Air is to inflate the preform as much as possible to the final shape of the container. The setting of the Primary Blow Delay time is one of the most critical processing adjustments that can be made in the molding process. Very small changes can have a significant effect on the container quality. There is no "correct" setting for Primary Blow Delay . The optimum setting will depend on many other factors upstream of the stretch blow process and it is also important to understand that the optimum setting will change if one of those upstream conditions changes. Therefore, adjusting the Primary Blow Delay time should be one of the last processing adjustment to be made when setting up a machine. If Primary Blow Delay is too early, the container may suffer from neck rings or off center gates. If it is too late, the shoulder may show a grainy appearance, there may be a constriction or the preform may split in the body. If there is insufficient infl...

4. Gage repeatability & reproducibility (R&R) test - Validation procedure for injection molds

Image
The fourth step in validating a injection mold with the overall process shown in figure injection mold validation flow chart is gage repeatability & reproducibility (R&R) test . The steps before: 1. Mold certification 2. Dry cycle mold 3. Process stability test Purpose: The purpose of the gage R&R analysis is to quantify the magnitude of variation of a measurement system. To ensure the benefit derived from using measurement data is of value and cost effective, attention must be focused on the quality of the measurement data. One of the most common reasons for low-quality data is too much variation in the measurement data. For example, a measurement system with a large amount of variation may not be appropriate for use in analyzing an injection molding process because the measurement system’s variation may mask the variation in the injection molding process. A gage is any device used to obtain measurements. This includes devices like coordinate measurement machines, verni...

3. Process stability test - Validation procedure for injection molds

The third step in validating an injection mold according to injection mold validation flow chart is dry cycle mold is process stability test . The steps before are: 1. Mold certification 2. Dry cycle mold Purpose: The purpose of the process stability test is to identify any gross mechanical design/construction flaws which will cause part variation over time. In addition, the process stability must be established with no short shots, flash, etc., prior to running designed experiments. The test is run at mid-range resin molding conditions for a period of time to allow thermal expansion equilibrium. In most instances, the mold builder may already have a process where the mold could run comfortably for several hours. During the process stability test the mold must run with one ejection stroke unless it was designed to cycle with multiple strokes. A robust ejection system will be able to eject the part and runner with one ejection stroke. Multiple ejection strokes per molding cycle incr...

Injection mold validation procedure

To validate an injection mold, there are numerous items one must take into consideration before the mold is completed and work is ready to begin. First, it is advisable to hold a mold design review meeting with all involved parties prior to tool manufacture. Invite the mold builder, hot runner supplier, steel supplier, press supplier, resin supplier, and a strategic molder for the design review. Involving everyone early on in the process and keeping them informed throughout the building of the mold avoids needless complications. Once all the suppliers have been identified it is vital that they are all given training on the injection mold validation procedure , IMVP. The training should be done well in advance of the first mold qualification, if you have a pilot tool stage this is an ideal time. It could be done whilst the production tools are being manufactured. It is strongly advised the tool builder is made aware of the requirements of mold certification (steel measurements) before...

Injection mold validation flow chart

Image
The following steps are required in validating a injection mold according to injection mold validation flow chart. 1. Mold certification 2. Dry cycle mold 3. Process stability test 4. Gage repeatability & reproducibility (R&R) test 5. Mold viscosity test 6. Balance of fill analysis 7. Gate freeze test 8. Commissioning (multi-cavity analysis) 9. Design of experiments 10. Qualification (process capability study) 11. Mold metal Adjustments - centering process 12. Verification (30-day run)

Random polypropylene copolymer

Image
Polypropylene is thermoplastic polymer consisting mainly of propylene come from a low pressure process based on catalysts and have generally linear polymer chain. There are three general types of polypropylene: homopolymer , random copolymer and impact or block copolymer . Random copolymer is produced by statistical insertion of units mainly ethylene . Through this, the glass transition temperature and melting point are lower than in homopolymer . Additionally we receive better mechanical properties in the temperature below zero (e.g. impact) and optical (transparency). Processing of random copolymer by injection molding considering properties mentioned above characterizes lower temperature (lower cycle time) and pressure. Application, e.g. thin wall and transparent products on the other hang thick wall, because of lower crystallization ratio (amorphous structure).

Polish polymer processing companies

Image
The story of Ponar Zywiec The successor of the machine factory with more than 100 years of traditions in construction of different kinds of machines, among them also machines with hydraulic drive, has specialized in construction of injection moulding machines and hydraulic presses for plastics and rubbers for above 30 years.

Mold balancing part 2/2

Mold balancing is design and mold manufacturing problem, machine, set up factors have lower impact. We can not skip factors result from viscosity changing, which are filling stage set up and polymer rheology. Factors which have impact on polymer flow parameters ( temperature , pressure , viscosity). It is important to secure symmetry distribution in velocity , shear rate , temperature , viscosity , for mold balancing . Title and body refer to mold, injection mold, but in the same way can be analyze any tool in polymer processing (e.g. extrusion die). Interesting problem is flow balancing in extrusion blow molding and parison centering, measured by wall thickness (e.g. botlle), the problem will be described soon. How mold balance impact parts? Each cavity is filled and packed in different stage for imbalanced mold. One cavity can be full filled during injection (over pack) and other partly filled during holding, when we fill shrinkage losses. Effect we receive parts with different st...

Mold balancing part 1/2

Image
Does your mold balanced? There will be the part of just preparing problem for mold balancing . Fundaments with mechanism in part 2/2 which formally is the first part. How to check mold balance? The eases way is to weigh parts from mold. I suggest go to the shop floor take the full shot and weigh on the most precise available weight. Date you can compile in the form presents below. The best you can do is to take more than one shot and count the average from the same cavity. You have two ways, try both, count deviation from maximum weight (first way) and from average weight (second way) for all cavities. Formulas are in the table, where indexes; m – maximum weight from all cavities, n – weight for the variable cavity, a – average weight for all cavities. Few conclusions from the above example. Cavities 7 and 10 are extreme first is the most second the least filled. Deviation from average gives the tendency +/- from average. Cavities 9 and 10 are the worst balanced. I would a...